  MODELE FES 1500W
-05V
FES 1500W
-12V
FES 1500W
-15V
FES 1500W
-24V
FES 1500W
-48V
INPUT  VOLTAGE,FREQUENCY  AC 99V ~ 132V / AC 198V ~ 264V (DC 140 ~ DC187V / DC 240~370V) , Selectable, 47~63Hz
 CURRENT (A) 220V 15 13 13 13 13
 EFFICIENCY (%) 220V 85 87 89 90 92
 INRUSH CURRENT (A)  20A typ(AC IN 110V, Io=100%) 40A typ(AC IN 220V, Io=100%) at cold start.
 LEAKAGE CURRENT (mA)
 (at 220VAC, 60Hz)
0.5<
OUTPUT  VOLTAGE (V) 5 12 15 24 48
 CURRENT (A) 300 125 100 60 30
 LINE REGULATION (mV) 45 45 64 95 200
 LOAD REGULATION (mV) 500 72 90 150 290
 RIPPLE, NOISE (mVp-p) 120 180 180 250 400
 OUTPUT VOLTAGE
 ADJ. RANGE (V)
4~6 9.6~14.4 12~18 19~28 38~52
 O.V.P (V) 6.25~7.25 15~17 18~21 30~35 55~64
 START-UP TIME (mS)  100 Max (AC IN 187V Io=100%)
 HOLD-UP TIME (mS)  10 Typ (AC IN 187V Io=100%)
 PROTECTION
CIRCUIT
 OVER CURRENT
 PROTECTION
 Works at over 110% of rating and recovers automatically
 OVER VOLTAGE  PROTECTION  Works at 115 ~ 140% of rating
ISOLATION  INPUT-OUTPUT  AC 3,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity)
 INPUT-CASE*FG  AC 2,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity)
 OUTPUT-CASE  AC 500V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity)
ENVIRONMENT  OPERATING TEMP.
 AND HUMID.
 -10~+50℃,20~90% RH(Non Condensing)
 VIBRATION  10~55Hz at 1G 3 minutes periods, 30 minutes along X,Y and Z axis
 IMPACT  10G for 20ms, Once on each X, Y and Z axis
SAFETY AND NOISE
REGULATIONS
 SAFETY
 REGULATION
 Meets UL 1950, CSA-22.2 , EN60950
 LINE CONDUCTED
 RF VOLTAGE
 Conducted EMI Meets FCC Class A
OTHERS  DIMENSION  126.0×285.0×85.0(L×W×H)
 QUALITY ASSURANCE  3 Year Warranty