MODELE FOS 200-12 FOS 200-24 FOS 200-36 FOS 200-48
AC IN PUT 50/60Hz  CURRENT [A] 220V 1.7A ~ 220VAC
 EFFICIENCY [%] 220V 89% 90% 91% 91%
 INRUSH CURRENT COLD START 75A(twidth=570㎲ measured at 50% Ipeak) at 230VAC
DC OUTPUT  VOLTAGE (V) 12V 24V 36V 48V
 CURRENT (A) 16A 8A 5.5A 4A
 LINE REGULATION (mV) ±1.0% ±1.0% ±1.0% ±1.0%
 LOAD REGULATION (mV) ±1.0% ±1.0% ±1.0% ±1.0%
 RIPPLE, NOISE (mVp-p) 200mVp-p 250mVp-p 200mVp-p 300mVp-p
 OCP  OVER CURRENT
 PROTECTION
 > 120%
ELECTRICALLY
ISOLATION
 WITHSTAND VOLTAGE  I/P-O/P,FG:2KVAC I/P-FG:2KVAC
 ISOLATION RESISTANCE  I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
ENVIRONMENT  WORKING TEMP.  -40 ~ +70℃
 WORKING TEMP.HUMIDITY  20 ~ 95% RH Non-Condensing
 STORAGE TEMP.,HUMIDITY  -40 ~ +80℃,10 ~ 95% RH
 TEMP. COEFFICIENT  ±0.03%/ (0~50)
 VIBRATION  10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,Y,Z sxes
SAFETY AND EMC  SAFETY REGULATION KC,CE
 EMC Compliance to EN55015, EN55022 (CISPR22) Class B
DIMENSION    218×63×48(L×W×H)