MODELE |
FPS 1000-12 |
FPS 1000-24 |
FPS 1000-36 |
FPS 1000-48 |
AC INPUT
99~305V
50/60Hz |
CURRENT [A] |
220V |
12A / 115VAC 6A / 230VAC 5.4A / 277VAC |
EFFICIENCY(typ.) [%] |
220V |
91% |
94% |
95% |
95% |
POWER FACTOR |
220V |
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load |
INRUSH CURRENT |
COLD START 75A(twidth=570㎲ measured at 50% Ipeak) at 230VAC |
DC OUTPUT |
VOLTAGE |
12V |
24V |
36V |
48V |
VOLTAGE ADJ RANGE |
10.2~12.8V |
20.4~25.6V |
30.5~38.5V |
40.8~51.2V |
CURRENT |
50A/83.3A(P-P) |
40A/41.6A(P-P) |
27.7A |
20.8A |
CURRENT ADJ RANGE |
30~60A |
20~40A |
14~27.7A |
11~20.8A |
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
RIPPLE & NOISE (max.) |
250mVp-p |
3250mVp-p |
500mVp-p |
500mVp-p |
OCP/OVP |
OVER CURRENT
PROTECTION |
95 ~ 108% |
Constant current lomiting, recovers automatically after fault condition is removed |
OVER VOLTAGE
PROTECTION |
13.5 ~ 18V |
27 ~ 34V |
43 ~ 49V |
55 ~ 63V |
ELECTRICALLY
ISOLATION |
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P,I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH |
ENVIRONMENT |
WORKING TEMP. |
-40 ~ +70℃ |
WORKING TEMP.HUMIDITY |
20 ~ 95% RH Non-Condensing |
STORAGE TEMP.,HUMIDITY |
-40 ~ +80℃,10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/℃ (0~50℃) |
VIBRATION |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,Y,Z sxes |
SAFETY AND EMC |
SAFETY REGULATION |
UL8750,CAS C22.2 No.250.0-08,EN61347-1,EN61347-2-13 independent IP65
or IP67, design refer to UL60950-1 |
EMC |
Compliance to EN55015, EN55022 (CISPR22) Class B |
DIMENSION |
|
477×173×111(L×W×H) |
|
|
|
|
|
|