FWS 120w
  • FWS 15w
  • FWS 30w
  • FWS 60w
  • FWS 80w
  • FWS 120w
  • FWS 150w
  • FWS 350w
  • FWS 600w
  MODELE FWS 120W
-05V
FWS 120W
-12V
FWS 120W
-15V
FWS 120W
-24V
FWS 120W
-48V
INPUT  VOLTAGE,FREQUENCY  AC 85~264V / DC 120~370V, 47~63Hz
 CURRENT (A) 110V 1.5 1.5 1.5 1.5 1.5
220V 0.8 0.8 0.8 0.8 0.8
 EFFICIENCY (%) 110V 82 84 86 88 89
220V 86 87 87 91 91
 INRUSH CURRENT (A)  20A typ(AC IN 110V, Io=100%) 40A typ(AC IN 220V, Io=100%) at cold start.
 LEAKAGE CURRENT (mA)
 (at 220VAC, 60Hz)
0.5<
OUTPUT  VOLTAGE (V) 5 12 15 24 48
 CURRENT (A) 24 10 8 5 2.5
 LINE REGULATION (mV) 21 48 57 98 190
 LOAD REGULATION (mV) 97 97 125 187 380
 RIPPLE, NOISE (mVp-p) 100 150 150 200 250
 OUTPUT VOLTAGE
 ADJ. RANGE (V)
4~6 9.6~14.4 12~18 19.2~28.8 38.4~52.8
 O.V.P (V) 6.25~7.25 15~17.4 18~21.8 30~34 55~63
 START-UP TIME (mS)  100 Max (AC IN 187V Io=100%)
 HOLD-UP TIME (mS)  10 Typ (AC IN 187V Io=100%)
 PROTECTION
CIRCUIT
 OVER CURRENT
 PROTECTION
 Works at over 110% of rating and recovers automatically
 OVER VOLTAGE
 PROTECTION
 Works at 115 ~ 140% of rating
ISOLATION  INPUT-OUTPUT  AC 3,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity)
 INPUT-CASE*FG  AC 2,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity)
 OUTPUT-CASE  AC 500V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity)
ENVIRONMENT  OPERATING TEMP.
 AND HUMID.
 -10~+50℃,20~90% RH(Non Condensing)
 VIBRATION  10~55Hz at 1G 3 minutes periods, 30 minutes along X,Y and Z axis
 IMPACT  10G for 20ms, Once on each X, Y and Z axis
SAFETY AND NOISE
REGULATIONS
 SAFETY
 REGULATION
 Meets UL 1950, CSA-22.2 , EN60950
 LINE CONDUCTED
 RF VOLTAGE
 Conducted EMI Meets FCC Class A
OTHERS  DIMENSION  82.0×163.0×38.0(L×W×H)
 QUALITY ASSURANCE  5 Year Warranty