MODELE |
FES 600W
-05V |
FES 600W
-12V |
FES 600W
-15V |
FES 600W
-24V |
FES 600W
-48V |
INPUT |
VOLTAGE,FREQUENCY |
AC 187~264V / DC 240~370V, 47~63Hz |
CURRENT (A) 220V |
4 |
3.6 |
3.6 |
3.6 |
3.6 |
EFFICIENCY (%) 220V |
85 |
88 |
90 |
91 |
92 |
INRUSH CURRENT (A) |
40A typ(AC IN 220V, Io=100%) at cold start. |
LEAKAGE CURRENT (mA)
(at 220VAC, 60Hz) |
0.5< |
OUTPUT |
VOLTAGE (V) |
5 |
12 |
15 |
24 |
48 |
CURRENT (A) |
120 |
50 |
40 |
25 |
12.5 |
LINE REGULATION (mV) |
48 |
48 |
60 |
96 |
190 |
LOAD REGULATION (mV) |
72 |
72 |
90 |
140 |
280 |
RIPPLE, NOISE (mVp-p) |
100 |
160 |
160 |
250 |
390 |
OUTPUT VOLTAGE
ADJ. RANGE (V) |
4~6 |
9.6~14.4 |
12~18 |
19.2~28.8 |
35.4~52.8 |
O.V.P (V) |
6.25~7.25 |
15~17.4 |
18.8~26.8 |
30~34 |
55~64.8 |
START-UP TIME (mS) |
100 Max (AC IN 187V Io=100%) |
HOLD-UP TIME (mS) |
10 Typ (AC IN 187V Io=100%) |
PROTECTION
CIRCUIT |
OVER CURRENT
PROTECTION |
Works at over 110% of rating and recovers automatically |
OVER VOLTAGE
PROTECTION |
Works at 115 ~ 140% of rating |
ISOLATION |
INPUT-OUTPUT |
AC 3,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity) |
INPUT-CASE*FG |
AC 2,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity) |
OUTPUT-CASE |
AC 500V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity) |
ENVIRONMENT |
OPERATING TEMP.
AND HUMID. |
-10~+50℃,20~90% RH(Non Condensing) |
VIBRATION |
10~55Hz at 1G 3 minutes periods, 30 minutes along X,Y and Z axis |
IMPACT |
10G for 20ms, Once on each X, Y and Z axis |
SAFETY AND NOISE
REGULATIONS |
SAFETY
REGULATION |
Meets UL 1950, CSA-22.2 , EN60950 |
LINE CONDUCTED
RF VOLTAGE |
Conducted EMI Meets FCC Class A |
OTHERS |
DIMENSION |
84.0×174.0×63.0(L×W×H) |
QUALITY ASSURANCE |
3 Year Warranty |