MODELE |
FES 80W
-05V |
FES 80W
-12V |
FES 80W
-15V |
FES 80W
-24V |
FES 80W
-48V |
INPUT |
VOLTAGE,FREQUENCY |
AC 187~264V / DC 240~370V, 47~63Hz |
CURRENT (A) 220V |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
EFFICIENCY (%) 220V |
84 |
86 |
86 |
90 |
90 |
INRUSH CURRENT (A) |
40A typ(AC IN 220V, Io=100%) at cold start. |
LEAKAGE CURRENT (mA)
(at 220VAC, 60Hz) |
0.5< |
OUTPUT |
VOLTAGE (V) |
5 |
12 |
15 |
24 |
48 |
CURRENT (A) |
16 |
6.7 |
5.4 |
3.4 |
1.7 |
LINE REGULATION (mV) |
20 |
47 |
58 |
94 |
195 |
LOAD REGULATION (mV) |
43 |
97 |
115 |
195 |
375 |
RIPPLE, NOISE (mVp-p) |
100 |
150 |
150 |
200 |
200 |
OUTPUT VOLTAGE
ADJ. RANGE (V) |
4~6 |
9.6~14.4 |
12~18 |
19.2~28.8 |
38.4~52.8 |
O.V.P (V) |
6.25~7.25 |
15~17.4 |
18~21.8 |
30~34 |
55~63 |
START-UP TIME (mS) |
100 Max (AC IN 187V Io=100%) |
HOLD-UP TIME (mS) |
10 Typ (AC IN 187V Io=100%) |
PROTECTION
CIRCUIT |
OVER CURRENT
PROTECTION |
Works at over 110% of rating and recovers automatically |
OVER VOLTAGE
PROTECTION |
Works at 115 ~ 140% of rating |
ISOLATION |
INPUT-OUTPUT |
AC 3,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity) |
INPUT-CASE*FG |
AC 2,000V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity) |
OUTPUT-CASE |
AC 500V 1 minute, DC 500V 100㏁ (At RoomTemperature & Humidity) |
ENVIRONMENT |
OPERATING TEMP.
AND HUMID. |
-10~+50℃,20~90% RH(Non Condensing) |
VIBRATION |
10~55Hz at 1G 3 minutes periods, 30 minutes along X,Y and Z axis |
IMPACT |
10G for 20ms, Once on each X, Y and Z axis |
SAFETY AND NOISE
REGULATIONS |
SAFETY
REGULATION |
Meets UL 1950, CSA-22.2 , EN60950 |
LINE CONDUCTED
RF VOLTAGE |
Conducted EMI Meets FCC Class A |
OTHERS |
DIMENSION |
82.0×133.5×38.0(L×W×H) |
QUALITY ASSURANCE |
3 Year Warranty |